How to adjust honeywell thermostat heat anticipator

how to adjust honeywell thermostat heat anticipator

Thermostat Heat Anticipator Adjustment (A Simple Guide)

How to Adjust a Honeywell Thermostat Heat Anticipator Step 1. Adjust the thermostat dial to the farthest point toward the left to check the system's heating operation. Step 2. Set the system switch to the left, or 'Cool,' setting if the unit is fitted with a sub base. Lower the Step 3. Remove. To accurately adjust a heat anticipator on your room thermostat it requires an amp probe or am-meter as they are sometimes called. Care needs to be taken at this point if you intend to use a jumper and a meter to measure heat anticipation. Remove one of the wires, usually red or white.

InspectAPedia tolerates no conflicts of interest. How to adjust honeywell thermostat heat anticipator have no relationship with advertisers, products, or services discussed at this website. Thermostat in question anticipaotr a Dayton 2E I did not find any too info online about this model. Perhaps as old as the house, mid 70's. I had touched it up with a bit of deoxit this fall.

Thegmostat be interested to see how sungle digit outside temps change the indoor temp swing but right now its less than 2 degrees.

Ill post a couple and let you decide whats helpful. Tom Nice going, and thanks for the feedback. It would be helpful to know the brand and model of the thermostats involved. Perhaps you could have attach a photo. Thank you for sharing your expertise regarding thermostat setup. I live in a 's ranch house equipped with electric baseboard throughout. Line voltage thermostats in the bedrooms provide consistent temperature but a large part of the house is controlled by an old Dayton low voltage thermostat that would allow a degree temperature swing.

Ive managed to adjust that down to hineywell. Much better! Larry please check out the three approaches to deciding on the thermostat heat anticipator settings given in the article above. One of those three is a useful Table of How to get to macritchie treetop walk Heat Anticipator Settings That you could follow if you have no other information.

I'm talking a bit beyond my expertise here so you should consider this an opinion only. Ring we're discussing steam Heating and not hot water heating if there is an overshoot problem I would have dress that by installing the proper steam vents on the radiators.

I might need an adjustable bed. That's because it may be but events are taking so long to vent air but the whole heating cycle is being extended. I also would look carefully at the thermostat location. Not really. I would expect the overshoot problem to be most serious if you have large cast iron hot water how to braise pork chops radiators.

Is that the case? If so you might consider some thermostatically operated radiator valves. The product has draw of. Any suggestions. Try the search box just below, or if you prefer, post a question or comment in the Comments box how to adjust honeywell thermostat heat anticipator and we will respond promptly.

Note: appearance of your Comment below may be delayed: if your comment contains an image, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay. Just ask us! Search the InspectApedia website.

Comment Form is loading comments Tel: Email: info carsondunlop. Carson Dunlop Associates' provides extensive home inspection education and report writing material. The text is intended as anticipatr reference guide to help building owners operate and maintain their home effectively. Field inspection worksheets are included at the back of what is watch in spanish volume.

Why Is The Anticipator Setting Important?

Use the manufacturer's recommended thermostat heat anticipator settings based on printed control circuit data. The heat anticipator Amps setting should be set to match the current (Amp) rating stamped on the name plate of the primary control that the thermostat is controlling. Below on this page at ANTICIPATOR SETTINGS by HEATING CONTROL. Jun 21,  · How to Adjust a Honeywell Thermostat Heat Anticipator Adjust the thermostat dial to the farthest point toward the left to check the system's heating operation. Set the system switch to the left, or 'Cool,' setting if the unit is fitted with a sub base. . Q&A on How & Why to Adjust the Heat Anticipator on a Room Thermostat. These questions & answers on settings for the thermostat heat anticipator were posted originally at HEAT ANTICIPATOR ADJUSTMENT - be sure to review the guidance found there. Photo: heat anticipator in a Dayton 2E room thermostat cited by Tom below. [Click to enlarge any image].

InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website. We explain how to test the heat anticipator on a thermostat, and we describe the conditions necessary for a heat anticipator on a room thermostat to work properly in the first place. We also explain the difference between the job of the thermostat heat anticipator and the differential settings on a heating system aquastat or similar control.

The purpose of a thermostat heat anticipator is to "de-sensitize" the thermostat so that when actual room temperature is hovering close to the set temperature on the thermostat, the thermostat switch won't keep switching the air conditioner or heating system on and off too often - which can damage the equipment. Properly adjusted a heat anticipator also prevents the room from getting warmer than the thermostat set temperature, and it prevents the heat from shutting off before the room has reached the thermostat set temperature.

In our photo you can see our pointer hovering over fine nichrome wire wound around a triangular piece of plastic forming a variable heating element and you can see at center of the photo a flat copper arm which can be moved to slide a contact to different positions along the wound variable resistor.

The triangular pointer on the copper arm in my photo has an opening which helps read the exact position to which the heat anticipator has been set. Behind the pointer you can see a silver scale with different amp readings which are explained below. Inserting a small tool or pencil point into the open copper triangle allows sliding the antipator lower towards higher or lower numbers. As you'll read in these articles, other thermostat heat anticipators may use different ranges of Amps and many modern digital and programmable thermostats don't use a heat anticipator at all.

If you click to enlarge the photo above you can see the amperage level to which this heat anticipator had been set when we took this picture. Adjusting the anticipator up or down to higher or lower Amps numbers will lengthen or shorten the heat-on or cooling-on cycle.

Watch out : unless you are having a problem with the thermostat's behaviour, don't fool with the heat anticipator - leave it as it was set by the installer. But if your heating system is oscillating or "seeking" and flipping the heat or air conditioner on and off when room temperature gets close to the thermostat set temperature.

THEN yes - the heat anticipator might enjoy being adjusted more properly and you might enjoy the result. The shortest burner-on time will be when the heat anticipator puts out the most heat. This warms up the thermostat's room temperature sensor and therefore tells the thermostat the room is up to set temperature earliest.

The longest burner-on time will be when the heat anticipator puts out the least heat , thus does not turn off heat early, thus lets the burner keep running longer. But look again more-closely at that arrow inside our red circle.

It is pointing to the left towards higher numbers on the scale. At higher numbers the heat anticipator draws less current so the little heating wire heats up less so the heating system will run longer. Take a closer look at the flat-wound nichrome wire heat anticipator and the path of current flow.

When the pointer is towards the right - lower - towards the 0. Jaffe When the pointer is moved towards the left - higher - towards the 1. A less-confusing illustration of a heat anticipator is this SlantFin thermostat - actually manufactured by Honeywell. Rather than a wind of wire around a triangular carrier as inthe T87 above the SlantFin thermostat heat antipator is a single strand of nichrome wire is bent into a circular shape.

At the lower shorter heat-on end of the scale is. Current flow is through the rivet in the center of the metal pointer, along the length of the metal pointer to its point of contact on the nichrome wire, and then through the nichrome wire to that solder blob that connects the. The longest heating cycle or heat-on at this thermostat will at the 0.

The thermostat's bimetalic spring room temperature sensor behind the white dial won't be getting much extra warmth from the heat anticipator. The shortest heating cycle or heat-on time at this SlantFin thermostat should be at the 0. Watch out : on most heat anticipators there will be both an Amps Scale initially set to match the measured amperage of the thermostat circuit AND an arrow telling you which way to move the pointer for a longer heat-on cycle.

Don't simply trust "left or right" on your thermostat - read the scale and notice the arrow. Depending on your model thermostat and where the heat anticipator is found, left and right or up and down might be reversed from the images here, and some of the thermostat heat anticipators we examined have only a numeric scale, no arrows, so it's important to follow the manufacturer's instructions.

Below we provide specific heat anticipator setting recommendations as well as a description of which way to move the heat anticipator lever to change the thermostat's behavior to address room temperature overshoot. You will see that Honeywell's own instructions contradict one another depending on the thermostat model. If your heating system seems to be working OK, without excessive burner on-off cycling and without troubling room temperature overshoot, leave the heat anticipator alone.

If however you are an installer and want to precisely set up the heat anticipator on a thermostat if your thermostat has this feature , there are three ways you can choose the initial Amps setting. The initial settings are intended simply to make sure that we don't send too much or too little current amps through the little heating coil or wire that comprises the heat anticipator. Later we can fine-tune the heat anticipator by setting it further up or down if the room temperature at the end of the heat-on cycle is overshooting heat is on too long or under-shooting heat is not on long enough the thermostat setting.

Our sketch above, adapted from a Flair APVO2 two-wire thermostat whose the heat anticipator level and scale red arrow on the left side of the device. Interestingly the company referred to this as a "fixed anticipation" thermostat, but its installation instructions indicated a screw-secured heat anticipator pointer and an amperage scale on the device.

Forced warm furnaces continue to blow warm air for a minute or so after the thermostat stops calling for heat - in a purge heat from the furnace heat exchanger. Steam heat radiators have thermal mass and in my OPINION also tend to overshoot the thermostat set temperature but the presumption of the table above is that they don't.

Heat on too long : If the furnace stays on beyond the set temperature on the thermostat, move the heat anticipator DOWN by 0. Watch out : if you set the heat anticipator too low that causes too much current to flow through the heating coil and will creat too much heat inside the thermostat, shutting the system down too early - before the living space actually comes up to temperature.

This can lead to service calls complaining that the heat never reaches the thermostat set temperature. Heat cycle too short : if the furnace shuts off before the set temperature on the thermostat has been reached, move the heat anticipator pointer UP by 0.

Watch out : if you set the heat anticipator too high the heat anticipator doesn't draw enough current to heat up, so the heating system shuts off too late - the room overheats. This too can lead to service calls complaining of overheating beyond the thermostat setting. Additional heat anticipator settings and details are usually provided on the thermostat installation pamphlet provided by the manufacturer.

This thermostat has an adjustable heat anticipator and will operate properly only if this [heat anticipator resistor type] tiny in-thermostat heater is adjusted to match the current of the valve or relay. Set the heat anticipator to the heating boiler or furnace manufacturer's recommendation ,.

Rufus You might see the bulb move as the room temp is changing, THe best place to watch is right at the furnace: watch the fan limit control dial when the furnace is running.

If you see the dial rotate around to the upper limit and then the furnace stops you know the furnace itself is overheating. Thanks Dan, although I am not sure if I could test a fault in a dirty or malfunctioning heat anticipator this way directly, although I guess I could infer it by seeing if the furnace runs a long time by jumping it while in the basement. Am I correct in my assumption though that if the furnace was turning off the flames quickly because it was overheating the furnace that such a shut down would not be changing the positioning of the mercury bulb in the Honeywell,.

Thank you for the follow-up. It's easy to rule the thermostat in or out of any heating system malfunction question for simply removing the thermostat and it's wiring from the equation. That means disconnecting the thermostat wires at the heating system and simply connecting or jumping the two thermostat terminals there.

That's the same as a thermostat calling for heat. The reason I think it is a thermostat problem is because after it started happening I took off the cover to my old 25 year Honeywell and watched it as things progressed.

Because it was only blowing for a minute or so, this did not take long, and I would see that the mercury was moving over in the bulb and turning off what I am assuming you refer to as the "call for heat".

I am assuming that if it was the heat exchanger overheating, and the call for turning off the flames is coming from a controller in the furnace as opposed to the mercury in the bulb moving , that the problem is with the thermostat. I'm not an expert obviously, but assume if the shutoff was from overheating in the heat exchanger that the mercury in the bulb would remain in the "on" position, and that the only thing that controls the position of the mercury in the thermostat bulb is the thermostat itself?

Rufus Watch out: If your furnace is short cycling badly I suspect that the problem is NOT with the heat anticipator nor even the thermostat, but something more fundamental and critical, potentially unsafe.

In my case, I needed to go to an extreme to stop the short cycling, and on my Honeywell moved the anticipator ALL the way to the left, for the longest run time. I realize that the Honeywell warns not to go below. Also, some suggest to try to clean the internals of the thermostat when short cycling happens. I wanted to try that, as my Honeywell is 25 years old.

It does not look too bad inside actually, but when they say to clean it, what is the reason? Would dust make the heat anticipator not work? And how to clean? With a Qtip? Or just an airduster? What parts specifically? Some menion the coil, but the coil is not really exposed with a surface area that can be cleaned. Thank you! Take a look at your thermostat and see if it includes an adjustable heat anticipator such as we discuss above on this page. OR post photos of the thermostat front cover and interior and we can comment further.

The question of whether or not you need or should want a thermostat that includes a heat anticipator feature is discussed. Honeywell's Instructions for Setting the Heat Anticipator and an explanation of heat, resistance and recap of Ohm's law regarding heat anticipators.

This article series on room thermostats and heat anticipators continues discussion of the basics of heating or cooling system thermostats, their use, setting, and adjustment. Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly. Note: appearance of your Comment below may be delayed: if your comment contains an image, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator.

Apologies for the delay. Just ask us! Search the InspectApedia website. Comment Form is loading comments Enjoy the convenience of programming a thermostat from any location, using a simple graphical interface. No computer equipment or software is required. The book provides comprehensive coverage of wiring and technical specifications, and now includes increased coverage of combination boilers, recently developed control features and SEDBUK Seasonal Efficiency of Domestic Boilers in the UK boilers ratings, where known.

In addition to providing concise details of nearly different boilers fuelled by electric, gas, oil and solid fuel, and over programmers and time switches, this invaluable resource also features numerous easy-to-understand wiring diagrams with notes on all definitive systems. Brief component descriptions are provided, along with updated contact and website details for most major manufacturers.

Memphis, TN www. Catalog XHO Reprinted